[. . . ] Beforeusingthehumidifier, extendthecord andinspectforanysignofdamage. do noT usetheproductifthecordhasbeen damaged. Thisproducthasapolarizedplugasasafety feature(onebladeiswiderthantheother). Thisplugwillfitintoapolarizedoutletonly oneway. Iftheplugdoesnotfullyfitinto theoutlet, reversetheplug. Ifitstilldoes notfit, contactaqualifiedelectrician. do noTattempttodefeatoroverridethis feature. aLWaYSunplugandemptythehumidifier whenitisnotinoperationorwhileitis beingcleaned. [. . . ] PoWeR­PressthePOWERbutton tosetthehumidifiertoHI. Pressthe POWERbuttonagaintoturntheunit OFF. WheninitiallyturnedONafterbeing pluggedin, thehumidifierwill`beep' andalliconsonthescreenwillbe temporarilyilluminated. Afterafew seconds, theLCDiconswillturnOFF, andtheunitwillbeinstandbymode withthebacklightOFF. PressingPOWERoncewillsettheunit toHIandturnthebacklightON. The LCDscreenwilldisplaytheContinue message("CO%")whichmeansthe unitwillbecontinuouslyonHIuntil setotherwise. Afterafewseconds, the currentroomhumidityandtheROOM messagewillbedisplayed. Iftheunitispluggedinandhasbeen turnedONonce, turningtheunitOFF andbackONwilldisplaytheRelative Humidity(RH)valuelastused. SeTTInG­Thehumidifierhastwo settings:HIandLOW. PresstheSETTING buttonandtheunitwillloopsettings (HI-LOW-HI)whiletherespectiveiconis illuminated. ReSeT­Whenthewaterlevelistoo low, theunitwillturnitselfOFF. Pressing theRESETbuttonwillreactivatetheunit afteryouhaverefilledthetank. nITe GLoTM­PresstheNITEGLO buttontoturnthebluenightlight ONorOFF. 3. a. 4. 5. b. 6. c. 42999-01 06/07/2006 5 © 2006 Hunter Fan Company 42999_EngFr_WM Dig Humid. indd 5 6/7/06 1:25:22 PM operating Your humidifier 1 3 2 4 5 6 Lcd Messages 1. Misting control: Whenthehumidityis higherthanthesethumidity, theheater willstopmisting, andthemistingicon willblink. Whentheunitisinnormal mistingmode, themistingiconwillbe illuminated. continuous Indicator: WhentheLCD screendisplaystheCO%message, it willalsoilluminatethecontinuousicon, indicatingthehumidifierisworking continuously. Refill Warning: Whenthewaterlevel istoolow, theheaterwillstop. Therefill iconwillblinktoindicatethatthetank needstoberefilled. Afterrefillingthe watertank, youmustpresstheRESET buttontoreactivatetheunit. humidity Set Range:Humiditymay besetbetween40%RHand85%RH inincrementsof5%. Ifthehumidityis sethigherthan85%, theLCDscreen willdisplaytheCO%RHmessage, indicatingthehumidifierissettowork continuously. 5. humidity display Range:The humidityorROOMdisplayrangeis 40%to80%RH. TheLCDscreenwill displayLO%ifthehumidityintheroom islowerthan40%. Ifthehumidityin theroomishigherthan85%, theLCD screenwilldisplayHI%. Setting humidity: PressUPorDOWN tochangethehumiditysettingby5% upordown, respectively. TheLCDscreen willdisplaytheSETmessageandthe digitsonthescreenwillblinkfortwo secondsuntilyouchangethesetting. Oncethehumiditylevelisset, theLCD screenwilldisplaythecurrentroom humidityandtheROOMmessage. . 6. 3. 4. 42999-01 06/07/2006 6 © 2006 Hunter Fan Company 42999_EngFr_WM Dig Humid. indd 6 6/7/06 1:25:24 PM Refilling The Water Tank 1. Whenthewaterlevelislow, pushthePOWER buttontoturnthehumidifierOFFandunplug thehumidifier. TurntheWaterTankoverandunscrewthe TankCapbytwistingitcounterclockwise. MakesuretheWaterTankisproperlyseated ontheBaseorthehumidifierwillnotwork properly. Water Tank ENGLISH Base hunTeR WILL noT accePT ReSPonSIBILITY FoR daMaGe due To WaTeR SPILLaGe. MakesurethePowerButtonissettoOFFand plugthehumidifierintothewalloutlet. cauTIon: never plug in the humidifier while your hands are wet, as electric shock could occur. noTe:Letthehumidifiersitforoneminute afterrefillingthetank, beforeturningthe powerbackON. PushthePowerButtontoturnthehumidifier ON. Adjustthesettingasneeded. 4. ReplacetheTankCapbyscrewingitclockwise ontotheWaterTank. Makesurethatthetank capisproperlyseatedbeforescrewingitback ontothetanktoensureaproperseal. 42999-01 06/07/2006 7 © 2006 Hunter Fan Company 42999_EngFr_WM Dig Humid. indd 7 6/7/06 1:25:25 PM Reassembly of humidifier Parts Exhaust Grille Medicine Cup Water Tank Boiler Cover Tank Cap Base Boiling Chamber cleaning The humidifier and The Water Tank Manyregionshavehardwaterwithhigh concentrationsofminerals. Whenwater evaporatesfromtheCareFree®WarmMist Humidifier, mineralsmaybeleftbehind. These mineralscanformahardwhitescalewhichcan beremovedbyfollowingthecleaninginstructions. Thefrequencyofcleaningduetomineralbuildup variesdependingonthequalityofwateryouhave. [. . . ] Ifyourhumidifierwatertank, boilercover, boilingchamber, base, knobsortankcapfail atanytimewithinone(1)yearafterthedateofsaletoyouduetoadefectinmaterialor workmanship, wewillrepair, oratouroption, replacethewatertank, boilercover, boiling chamber, base, knobsortankcapfreeofchargeforpartsorlaboratournearestservicecenter oratourServiceDepartmentinMemphis, Tennessee. IFTHEORIGINALRESIDENTIALUSEROFCONSUMERPURCHASERCEASESTOOWNTHE HUMIDIFIER, THISWARRANTYANDANYIMPLIEDWARRANTYWHICHTHENREMAINSIN EFFECT, INCLUDINGBUTNOTLIMITEDTOIMPLIEDWARRANTYOFMERCHANTABILITYOR FITNESSFORAPARTICULARPURPOSE, AREVOIDED. NOWARRANTY, EXPRESSEDORIMPLIED, INCLUDINGANYWARRANTYOFMERCHANTABILITY ORFITNESSFORAPARTICULARPURPOSE, ISMADEINRESPECTTOTHEFILTER. THEWARRANTYISINLIEUOFALLOTHEREXPRESSWARRANTIES. THEDURATIONOF ANYIMPLIEDWARRANTY, INCLUDINGBUTNOTLIMITEDTOANYIMPLIEDWARRANTYOF MERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE, INRESPECTTOTHEMOTORIS EXPRESSLYLIMITEDTOTHEPERIODOFTHEEXPRESSWARRANTYSETFORTHABOVE. [. . . ]